Glasvezelkabels
Metaalvrije brandvertragende gepantserde kabel
GYFTZA53
FRP-kernelement · brandvertragend · dubbele mantel · 2–144 vezels
Een metaalvrije kern met FRP-trekelement en brandvertragende materialen door de hele opbouw, afgewerkt met een dubbele mantel. Voor tunnels, schachten en gebouwinvoeren waar een brandklasse gehaald moet worden en metaal ongewenst is.
Kenmerken
- Good mechanical and thermal performance
- FRP central strength member
- Hydrolysis resistant loose tube
- Tube filling compound ensures critical protection of fiber
- Specially designed stranded compact structure eliminating contraction of tubes
- LSZH sheath ensuring good flame-retardant performance
- Crush resistance and flexibility
- Water-blocking measures : - Loose tube gel-filled - 100% cable filling compound - APL moisture barrier - Corrugated steel tape (CST) enhancing moisture-proof
Toepassingen
Kwaliteit & conformiteit
GYFTZA53
Normen & certificeringen
Kwaliteitskenmerken
- Central strength member: FRP (non-metallic)
- Tensile strength (short / long term): 3000 N / 1000 N
- Crush resistance (short / long term): 1000 N / 300 N per 100 mm
- Operating temperature: -40 °C ~ +70 °C
- Storage temperature: -40 °C ~ +70 °C
Technische gegevens
GYFTZA53
| Fiber Type | G652D G655 G657 50/125 62.5/125 |
|---|---|
| Tensile Strength(N) | Long/Short Term:1000/3000 |
| Crush Resistance(N/100mm) | Long/Short Term:1000/3000 |
| Bending Radius(mm) | Static/Dynamic:12.5D/25D |
| Temperature(℃) | Storage /Operation:-40℃~70℃ |
The fibers are positioned in loose tubes that are made of high-modulus plastic and filled with tube gel. The tubes (and fillers) are stranded around a non-metallic central strength member to form a cable core. The core is filled with water blocking compound and is armored with laminated aluminum tape(APL). Then the cable core is covered with PE inner sheath. After the steel tape is longitudinally armored over the inner jacket, the cable is completed with a LSZH outer jacket.
| Counts | 2-30 | 32-36 | 38-60 | 62-72 | 74-96 | 98-120 | 122-144 | 146-216 | 218-288 |
|---|---|---|---|---|---|---|---|---|---|
| Max.fiber counts per tube | 6 | 6 | 12 | 12 | 12 | 12 | 12 | 12 | 12 |
| Units(Tubes or Fillers) | 6 | 6 | 6 | 6 | 8 | 10 | 12 | 18 | 24 |
| Cable Diameter(mm) | 13.9 | 13.9 | 14.7 | 14.7 | 16.0 | 17.4 | 18.9 | 19.3 | 21.3 |
| Weight(Kg/km) | 216 | 216 | 239 | 239 | 278 | 323 | 373 | 382 | 460 |
| Fiber Type | G652D G655 G657 50/125 62.5/125 | ||||||||
| Tensile Strength(N) | Long/Short Term:1000/3000 | ||||||||
| Crush Resistance(N/100mm) | Long/Short Term:1000/3000 | ||||||||
| Bending Radius(mm) | Static/Dynamic:12.5D/25D | ||||||||
| Temperature(℃) | Storage /Operation:-40℃~70℃ | ||||||||
Voorbeeldfoto
Referentiefoto van dit producttype – niet het exacte geleverde artikel.
Verwante types
ADSS volledig diëlektrische zelfdragende kabel
Volledig diëlektrische luchtkabel die zijn eigen gewicht draagt over overspanningen tot 600 m (800 m op aanvra...
Gestrande losse-buiskabel met APL-pantsering
Het werkpaard onder de buitenkabels: gelgevulde PBT-buisjes gestrand rond een stalen kernelement, aluminium-po...
Bekijk details →
Gestrande losse-buiskabel met staalband-pantsering
Dezelfde gestrande losse-buiskern als GYTA, maar gepantserd met gegolfde staalband (PSP) in plaats van alumini...
Bekijk details →
Dubbel ommantelde gepantserde buitenkabel
Een GYTS-kern met een tweede polyethyleenmantel. De extra mantel houdt de kern droog en intact als knaagdieren...
Bekijk details →Offerte aanvragen
Offerte aanvragen voor GYFTZA53
Stuur ons type, aantal en bestemming. Een engineer antwoordt, geen automatisch bericht.