La costruzione da esterno più diffusa: tubetti in PBT riempiti di gel cordati intorno a un elemento centrale in acciaio, armatura in laminato alluminio-polietilene, guaina in PE. Leggero rispetto alla sua resistenza; l'armatura in alluminio contiene il peso dove l'acciaio sarebbe eccessivo.

Caratteristiche

  • Good mechanical and temperature performance
  • Steel wire as the central strength member
  • Hydrolysis resistant loose tube
  • Fiber gel ensures critical protection of fiber
  • Specially designed stranded compact structure eliminating contraction of tubes
  • Rugged, durable PE jacket protects against UV radiation, fungus etc.
  • Crush resistance and flexibility
  • Water-blocking measures : - Loose tube gel-filled - 100% cable filling compound - APL moisture barrier

Applicazioni

DuctNon Self-supporting Aerial Installation

Qualità e conformità

GYTA

Punti di forza qualitativi

  • Central strength member: Phosphated steel wire
  • Tensile strength (short / long term): 3000 N / 1000 N
  • Crush resistance (short / long term): 1000 N / 300 N per 100 mm
  • Operating temperature: -40 °C ~ +70 °C
  • Storage temperature: -40 °C ~ +70 °C

Specifiche tecniche

GYTA

Parameter
Fiber TypeG652D G655 G657 50/125 62.5/125
Tensile Strength(N)Long/Short Term:600/1500
Crush Resistance(N/100mm)Long/Short Term:300/1000
Bending Radius(mm)Static/Dynamic:10D/20D
Temperature(℃)Storage /Operation:-40℃~+70℃

The fibers are positioned in a loose tube made of high modulus plastic and filled with gel. Tubes (and fillers) are stranded around the metallic strength member to form the cable core filled with water blocking compound. An Aluminum tape (APL) is armored longitudinally around the core. Finally a PE jacket is extruded.

Counts 2-30 32-36 38-60 62-72 74-96 98-120 122-144 146-216 218-288
Max.fiber counts per tube 6 6 12 12 12 12 12 12 12
Units(Tubes or Fillers) 5 6 5 6 8 10 12 18 24
Cable Diameter(mm) 9.2 9.6 9.7 10.2 11.5 12.8 14.0 14.3 16.2
Weight(Kg/km) 77 91 87 105 128 152 178 185 232
Fiber Type G652D G655 G657 50/125 62.5/125
Tensile Strength(N) Long/Short Term:600/1500
Crush Resistance(N/100mm) Long/Short Term:300/1000
Bending Radius(mm) Static/Dynamic:10D/20D
Temperature(℃) Storage /Operation:-40℃~+70℃

Immagine illustrativa

Foto di riferimento di questo tipo di prodotto, non l'articolo esatto spedito.

Richiedi un preventivo

Richiedi un preventivo per GYTA

Inviaci modello, quantità e destinazione. Risponde un tecnico, non un risponditore automatico.

Utilizziamo i tuoi dati solo per rispondere a questa richiesta. Vedi l'informativa sulla privacy.