Italiano
CR Fiber Optics

Serve un preventivo o una scheda tecnica?

Indicaci modello, quantità e porto di destinazione. La maggior parte delle richieste riceve risposta entro un giorno lavorativo.

Per operatori FTTH regionali

Quale cavo per quale tratta

Un impianto FTTH completo ha sei livelli e non vogliono lo stesso cavo. Qui sotto cosa forniamo per ciascuno e cosa definire prima di chiedere un prezzo.

Applicazioni

The fibre itself

Everything else is packaging. Get the fibre grade right first — it decides your loss budget and how tight a bend the install crew can get away with.

Da confermare prima dell'ordine

G.652.D for the outside plant; G.657.A1 or A2 anywhere the route gets tight — risers, wall boxes, pre-terminated assemblies.

Vedi scheda ↗

Applicazioni

Feeder — OLT to the primary splitter

High fibre count, long runs, ducted or direct-buried. This is the section you least want to dig up again, so armour and fibre count both want headroom.

Da confermare prima dell'ordine

Fibre count including spare (plan 30–50% above day-one demand), duct or direct burial, and whether rodents are a known problem on the route.

Vedi scheda ↗

Applicazioni

Distribution — splitter to street or building

Mid count, shorter runs, more joints. Handling matters more here than raw strength: your crews will be opening these all day.

Da confermare prima dell'ordine

Fibre count per branch, duct versus aerial, and the closure type you standardise on — tube count has to match it.

Vedi scheda ↗

Applicazioni

Aerial spans and shared poles

Where trenching is not worth it. If you are sharing poles with live power lines, the cable has to be all-dielectric — no metal anywhere.

Da confermare prima dell'ordine

Longest span in metres, whether the poles carry live LV/MV lines, and who owns them. Span length decides the construction, not the fibre count.

Vedi scheda ↗

Applicazioni

Drop — the last span to the subscriber

The highest volume item in any FTTH build and the one your install crews touch most. Strip time per drop, multiplied by thousands of homes, is real money.

Da confermare prima dell'ordine

Aerial or underground, span length, 1 / 2 / 4 core, and whether your crews field-connectorise or splice on site.

Vedi scheda ↗

Applicazioni

In-building — riser and floor distribution

Indoors in the EU this is where the fire regulations bite. Getting the class wrong is not a price difference, it is a failed inspection.

Da confermare prima dell'ordine

The CPR Euroclass your project specifies (Eca / Dca / Cca / B2ca) — it changes the sheath compound and therefore the lead time. Tell us at enquiry stage.

Vedi scheda ↗

Applicazioni

Tunnels, shafts and other awkward places

Rail tunnels, mine roadways, plant rooms. Fire performance and mechanical protection together, usually against a specification someone else wrote.

Da confermare prima dell'ordine

The exact standard the specification cites, plus whether metal is allowed in the construction at all.

Vedi scheda ↗

Gamma prodotti

Costruito su specifiche pubblicate

Ogni modello è corredato di scheda tecnica completa. I valori indicati sono valori di collaudo, non cifre di marketing.

Tutti i prodotti →

Norme e conformità

Norme e conformità

ISO 9001:2015 ISO 14001 IEC 60794 ITU-T G.652 / G.657 RoHS REACH CPR Eca

Serve un preventivo o una scheda tecnica?

Indicaci modello, quantità e porto di destinazione. La maggior parte delle richieste riceve risposta entro un giorno lavorativo.

Richiedi un preventivo Scrivici